| Set point range: |
AT1_: .04 to 3 fps (.012 to .91 mps)
AG1_: 1 to 90 fps (.3 to 27 mps) |
Strobe flash: |
_61_: 1 per second
_62_: N/ |
| Factory set point: |
AT1_: .2 fps (.06 mps)
AG1_: 10 fps (3 mps) |
Process temp: |
F: 32° to 140°
C: 0° to 60° |
| Repeatability: |
±.5% of set point @ fixed temp. |
Electronics temp: |
F: -40° to 140°
C: -40° to 60° |
| Response time: |
1-10 seconds |
Pressure: |
150 psi (10 bar) @ 25°C, derated @ 1.667psi (.113 bar) per °C above 25° C |
| Set point adjust: |
Potentiometer |
Wetted material: |
16__: PP-Ryton
36__: PVDF Kynar |
| Viscosity range: |
AT1_: 1-200 centipoise
AG1_: N/a |
Process mount: |
3/4" NPT (3/4" G) |
| Supply voltage: |
120/240 VAC @ 50-60 Hz |
Mount gasket: |
Viton |
| Contact type: |
(1) SPDT relay |
Enclosure rating: |
NEMA 4X (IP65) |
| Contact rating: |
250 VAC @ 10A |
Enclosure material: |
_61_: PP, UL94VO and polycarbonate
_62_: PP, UL94VO |
| Contact delay: |
0-60 seconds |
Conduit entrance: |
Single, 1/2" NPT |
| LED indication: |
Power, relay, and sensor status |
Classification: |
Geneerla purpose |
| Strobe type: |
_61_: Xenon tube
_62_: N/a |
CE compliance: |
EN 50082-2 immunity
EN 55011 emission
EN 61010-1 safety |