-Data Sheet-
-Manual-

LA12-7001
LA12-7061

LA12-1001
LA12-1061

LA12-5001
LA12-5061

 

The Cricket™ alphasonic transmitter provides contact level measurement for clean water or non-coating and scaling diluted corrosive liquids (atmospheric day tank and process vessel applications, potable water and malic acid media). Wave guides are available in three materials: PVC (LA12-70_1), PP (LA12-10_1), and PVDF (LA12-50_1); all are easily sized in the field.

 

-Specifications-

Range: 0.3' to 10' (9 cm to 3m) Electronics temp: F: -4° to 140°
C: -20° to 60°
Accuracy: ± 1% of span in air Pressure: Atmospheric
Resolution: 0.125" (3 mm) Enclosure rating: NEMA 4X (IP65)
LED indication: Power status Installed height: 5.9" (15 cm) above tank process mount
Supply voltage: 14-36 VDC Enclosure material: PP, UL94VO
Loop resistance: 600 Ohms @ 24 VDC

Guide material:

PVC, PP or PVDF Kynar®
Signal output: 4-20 mA, two-wire Process mount: 1" NPT (1" G)
Signal invert: 4-20 or 20-4 mA Mount gasket: Viton (G version only)
Calibration: Potentiometer Conduit entrance: Single, 1/2" NPT
Process temp: F: -40° to 140°
C: -40° to 60°
Classification: General purpose
Temp comp: Automatic CE compliance: EN 50082-2 immunity
EN 55011 emission

 